API PLAN 76


A containment seal chamber drain for non-condensing leakage on arrangement 2 unpressurized seals with containment seals. Used if the

pumped fluid does not condense at ambient temperatures.

Features


  • Avoids direct leakage of pumped media to the atmosphere and ensures almost no leakage from the outboard seal.
  • The vapors are directed to the vapor collection system.
  • This plan can be used with buffer gas (Plan 72) or without buffer gas (Plan 71).
  • Set the pressure transmitter alarm to a pressure of 0.7 bar (10 PSI) so as to trigger an alarm when the pressure in the vapor collection system increases. This indicates inboard seal leakage.
  • Ensure that the vent line is always open and an orifice is present to generate back pressure.
  • Ensure a low point condensate drain.
  • Check that the support to the harness piping is sufficient.
  • Use a minimum 1/2" (13 mm) tubing for the CSV line and ensure that the pipeline rises continuously upwards.
  • Do not use for condensing media.

Recommended Application


Remarks, Checkpoints :

  • For non-condensing media – typically high vapor pressure flashing light hydrocarbons.
  • For configurations utilizing an outboard containment seal – contacting or non-contacting type.

Recommended Application : 

  • For condensing media.
  • For configurations utilizing an outboard containment seal – contacting or non-contacting type.
  • Generally used in combination with a Plan 72 nitrogen purge.